Skip to content
CORVASEC — Knowledge Defends
Vulnerability Explorer›CVE-2026-112354
VULNERABILITY

CVE-2026-112354

Common Vulnerabilities and Exposures record

CRITICAL

Summary

Etrel INCH AC charging station management web interface prior to firmware versions 7.1.2 and 8.0.1 contains a hard-coded default credentials vulnerability that allows remote attackers to gain full Administrator access by authenticating with the factory-default account. Attackers can log in over cleartext HTTP to obtain complete charger configuration, OCPP ChargePoint Identity, and CSMS WebSocket connection details, enabling unauthorized administrative control of the charging station.

Risk

CVSS
9.3
Severity
CRITICAL
Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Timeline

Published
Nov 3, 2026 22:17
Modified
Nov 12, 2026 21:36
Last observed
Nov 12, 2026 17:00

CWE

CWE-1392

References