Skip to content
CORVASEC — Knowledge Defends
Vulnerability Explorer›CVE-2025-41109
VULNERABILITY

CVE-2025-41109

Common Vulnerabilities and Exposures record

HIGH

Summary

Ghost Robotics Vision 60 v0.27.2 includes, among its physical interfaces, three RJ45 connectors and a USB Type-C port. The vulnerability is due to the lack of authentication mechanisms when establishing connections through these ports. Specifically, with regard to network connectivity, the robot's internal router automatically assigns IP addresses to any device physically connected to it. An attacker could connect a WiFi access point under their control to gain access to the robot's network without needing the credentials for the deployed network. Once inside, the attacker can monitor all its data, as the robot runs on ROS 2 without authentication by default.

Risk

CVSS
8.7
Severity
HIGH
Vector
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Timeline

Published
Oct 22, 2025 09:15
Modified
Oct 8, 2026 11:10
Last observed
Oct 12, 2026 10:10

CWE

CWE-798

Affected product identifiers

cpe:2.3:o:ghostrobotics:vision_60_firmware:0.27.2:*:*:*:*:*:*:*
cpe:2.3:h:ghostrobotics:vision_60:-:*:*:*:*:*:*:*

References